USA Banner

Official US Government Icon

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure Site Icon

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

U.S. Department of Transportation U.S. Department of Transportation Icon United States Department of Transportation United States Department of Transportation
FHWA Highway Safety Programs

Safety Eligibility Letter SS-09B

Hardware Type:
Sign Supports, Mailboxes, and Delineator Posts
Code:
SS-09B
Date:
Testing Criteria:
NCHRP 350
Manufacturer:
Franklin Steel
Device Description:
Dual EZE-Erect in strong soil.
View PDF:
ss09b.pdf (82.68 KB)
Skip to contentUnited States Department of Transportation - Federal Highway Administration FHWA HomeFeedback

October 17, 1996

Refer to: HNG-14/SS-09B

Mr. James W. Young
Vice President
Sales and Marketing
Franklin Industries
P.O. Box 671
Franklin, Pennsylvania 16323

Dear Mr. Young:

This is in response to your September 16 letter to Mr. Nicholas Artimovich requesting the Federal Highway Administration's acceptance of our company's dual-post EXE-Erect system. Your letter was accompanied by a Southwest Research Institute report dated August 1987 on a triple-post support test (which did not pass) and calculations performed by Mr. Malcolm Ray indicating expected performance based on single-post test results.

Our Geometric and Roadside Design Acceptance letter Number SS-9, dated March 16, 1989, found single, 6.0-kg/m (4-pound/foot) EZE-Erect posts acceptable in both strong and weak soils. Some States have found two-EZE-Erect posts acceptable by virtue of an extrapolation of the results of the single-post tests. Mr. Ray's calculations that you provided show that the dual post support would meet the change-in-velocity criteria

The report of the triple-post test shows an excessive velocity change. However, this was predictable from the single-post testing. In fact, the energy dissipated per post in the triple-post test was very close to that in the comparable single-post test. This gives us confidence in the interpolation and extrapolation of the test data. Thus, from these data we can infer that a dual-post support will perform satisfactorily in the strong-soil conditions under which the three-post support was tested. Therefore, a dual-post EZE-Erect sign support system using posts of up to and including 6.0 kg/m will be acceptable for use in strong soil on the National Highway System when requested by a State. Our reason for excluding the dual posts in weak soil is the fact that doubling the energy dissipated in the low-speed, single-post test in weak soil predicts a dual-post energy loss at 98 percent of the allowable. We consider this too close for us to base our acceptance on the available data. In addition, in the single-post, weak-soil, low-speed test the post and stub pulled entirely out of the ground. While this, in and of itself, has not been used as a basis for disqualifying a breakaway system, it does cast doubt on the repeatability of the performance of the system and certainly requires caution in extrapolating the performance data.

Seppo I. Sillan, Acting Chief
Federal-Aid and Design Division

Geometric and Safety Design Acceptance Letter Number SS-09B


FHWA Safety Home | FHWA Home | Feedback

FHWA

United States Department of Transportation - Federal Highway Administration